COMPOUND PROFILE • SAN GF10

Grade Specification Overview

POLIMATRIX SAN GF10

Glass Reinforced SAN — SAN GF10

Glass fibre
10% wt%
Processing
Injection moulding
MFI
27 g/10 min
Heat / impact
HDT 105°C

Recommended for: Cross Flow Fans components, subject to dimensional, mechanical and processing validation.

Performance Profile

Qualitative Indicators — Typical values on TDS

Relative engineering performance ratings across key mechanical and thermal dimensions.

Tensile Stiffness
Excellent
Tensile Strength
High
Impact Resistance
Good
Heat Resistance (HDT)
High
Dimensional Stability
Excellent
Processability
High
Surface Finish
High

Key Formulation Characteristics

10% glass loading
Balanced stiffness
Good mould flow & surface finish
Reinforcement: 10% Glass Filled
Formulated for Injection Moulding

Typical Properties & ASTM Standards

Verified typical values for SAN GF10 as published on technical data sheet.

ASTM Standard Test Methods
Mechanical / Physical PropertyTest StandardTypical ValueUnit
Melt Flow Index (MFI / MFR)ASTM D123827g/10 min
Specific Gravity / DensityASTM D7921.10g/cm³
Tensile StrengthASTM D63855MPa
Flexural ModulusASTM D7906,000MPa
Izod Impact Strength (Notched)ASTM D2565.0kg·cm/cm
Heat Deflection Temperature (HDT / VSP)ASTM D648105°C
Flammability RatingUL 94HBRating
* Typical values, not specification limits. Values are for material selection purposes only.

Target Applications

Proven Air Conditioning components and commercial end-use parts moulded with SAN GF10:

Alternative & Sister Grades

Explore related SAN alloys or alternative reinforcement percentages:

Technical Assistance

Need Custom Formulation or Testing?

Our application development engineers can tailor filler content, melt flow index, UV stabilization, or masterbatch color matching to your specific molding window.

Consult Polymer Specialist
WhatsApp Us